SCTP Conformance Test For Retransmission Timer


Tool Version :REL_3_1_0
Test Program Version :REL_1_0_0

Start:2009/01/23 12:06:51
End :2009/01/23 12:06:51

No.Title ResultLogScriptPacketDump
(bin)

Handle T1-init Expiration




1INIT message is transmitted again if T1-Init timer expiresPASSXXXLink0
2Failure to receive INIT-ACK after retransmit times to 'Max.Init.Retransmits'PASSXXXLink0
3RTO is updated correctly if T1-init timer expires for a INIT messagePASSXXXLink0

Handle T1-cookie Expiration




4COOKIE-ECHO message is transmitted again if T1-cookie timer expiresPASSXXXLink0
5Failure to receive COOKIE-ACK after retransmit times to 'Max.Init.Retransmits'PASSXXXLink0
6Retransmit times for failure to receive COOKIE-ACK (retransmitted INIT message)PASSXXXLink0
7RTO is updated correctly if T1-Ccookie timer expires for a COOKIE-ECHO messagePASSXXXLink0

Handle T3-rtx Expiration




8DATA message is transmitted again if T3-rtx timer expiresPASSXXXLink0
9Failure to receive SACK after retransmit times to 'Association.Max.Retrans'PASSXXXLink0
10The counter of retransmissions shall be reset if the DATA chunk is acknowledgedPASSXXXLink0
11RTO is updated correctly if T3-rxt timer expires for a DATA messagePASSXXXLink0

Handle T2-shutdown Expiration




12SHUTDOWN message is transmitted again if T2-shutdown timer expiresPASSXXXLink0
13SHUTDOWN-ACK message is transmitted again if T2-shutdown timer expiresPASSXXXLink0
14Failure to receive SHUTDOWN-ACK after retransmit times to 'Association.Max.Retrans'PASSXXXLink0
15Failure to receive SHUTDOWN-COMPLETE after retransmit times to 'Association.Max.Retrans'PASSXXXLink0
16The counter of retransmissions shall be reset for a SHUTDOWN message if reception of DATA messagePASSXXXLink0
17RTO is updated correctly if T2-shutdown timer expires for a SHUTDOWN messagePASSXXXLink0
18RTO is updated correctly if T2-shutdown timer expires for a SHUTDOWN-ACK messagePASSXXXLink0

Handle T5-shutdown-guard Expiration




19Abort the association by sending an ABORT chunk if T5-shutdown-guard timer expiresPASSXXXLink0

Handle HEARTBEAT timer Expiration




20HEARTBEAT message is transmitted again if HEARTBEAT timer expiresPASSXXXLink0
21Failure to receive HEARTBEAT-ACK after retransmit times to 'Association.Max.Retrans'PASSXXXLink0
22RTO is updated correctly if HEARTBEAT timer expires for a HEARTBEAT messagePASSXXXLink0

Index
This Report was generated by TAHI IPv6 Conformance Test Suite