InitAckStreamMismatch.seq - INIT-ACK chunk is received with mismatch in the Outbound Stream and Inbound Stream parameters
To check that if INIT-ACK chunk is received with mismatch in the Outbound Stream
and Inbound Stream parameters then the endpoint should settle with minimum of
the two parameters.
./InitAckStreamMismatch.seq [-tooloption ...] -pkt ./InitAckStreamMismatch.def
-tooloption : v6eval tool option
See Also: ../common/STD_PKT_COMMON.def
../common/SCTP_COMMON.def
Association is not established between endpoint A and B. Also let the OS
of B is Z. Arrange data in endpoint A such that INIT-ACK message is sent
from endpoint A with MIS Y<Z.
Endpoint A Endpoint B ULP
(ESTABLISHED) (ESTABLISHED)
<----- Associate
<----------------- INIT
(OS = Y, MIS = Y)
INIT-ACK ----------------->
(OS = Z, MIS = Z, Z < Y)
<----------------- COOKIE-ECHO
COOKIE-ACK ----------------->
TEST DESCRIPTION:
1. Attempt to initiate an association from endpoint B to A. Send
INIT-ACK message with Maximal Inbound stream parameter less than
the Outbound Stream of B.
Record the message sequence using a signal emulator.
2. Check A: Either the association is aborted or COOKIE-ECHO is
received
3. Check B: Range of MIS Stream id in endpoint B is 0 to Y-1.
4. Check C: Was the message sequence as above.
Note: Association may be aborted in this case.
None
RFC 4960
5.1.1. Handle Stream Parameters
In the INIT and INIT ACK chunks, the sender of the chunk MUST
indicate the number of outbound streams (OSs) it wishes to have in
the association, as well as the maximum inbound streams (MISs) it
will accept from the other endpoint.
After receiving the stream configuration information from the other
side, each endpoint MUST perform the following check: If the peer's
MIS is less than the endpoint's OS, meaning that the peer is
incapable of supporting all the outbound streams the endpoint wants
to configure, the endpoint MUST use MIS outbound streams and MAY
report any shortage to the upper layer. The upper layer can then
choose to abort the association if the resource shortage is
unacceptable.
After the association is initialized, the valid outbound stream
identifier range for either endpoint shall be 0 to min(local OS,
remote MIS)-1.